Home/Pulse/Modules/LEM CAB 300 / CAB 500
- Current sensor / Built into Pulse

LEM CAB 300 / CAB 500.

Experimental

Built from the maker's protocol documents. Not yet confirmed against a capture from a real car.

- What Pulse reads from it
  • Pack current
- Notes from the profile

Current from a LEM CAB 300-C/SP3 or CAB 500-C/SP5 on frame 0x3C2, from LEM's datasheets. Not yet seen on a bus by Dynam. The id depends on the part: 0x3C2 is the CAB 500's default and the CAB 300-C/SP3-002 and -010; other CAB 300 variants send on 0x3C0 to 0x3C9 and will not match, and the ids of most parts can be reprogrammed. Some variants run at 250 kbit/s. The sign follows the arrow on the housing, which the datasheet does not tie to charge or discharge: the value is shown as sent. A value the sensor flags as failed is not shown. The CAB 1500 uses another frame layout and is not read.

KIND
Current sensor
MAKER
LEM
BUS SPEED
250 or 500 kbit/s
FAULTS READ
1
BUILT FROM
The maker's documents
PROFILE
V1.0 by Dynam Labs
- Turn it on
  1. In Pulse, open Settings → Vehicle → CAN modules.
  2. Choose Modules and pick LEM CAB 300 / CAB 500. It is already in the app.
  3. On a bus without a Dynam VCU, turn on Listen only for that vehicle, and Pulse sends nothing.
All modules