Bender ISOMETER iso165C.
Built from the maker's protocol documents. Not yet confirmed against a capture from a real car.
- Isolation resistance
- Isolation fault
Insulation resistance and the fault and warning flags from the iso165C's cyclic IMD_Info frame (0x37), from Bender's manual (D00154) and its DBC as kept in foxBMS. Not yet seen on a bus by Dynam, so the resistance is shown here and in Diagnostics and never on a dash. The iso165C runs at 250 kbit/s and the iso165C-1 at 500. The iso165C measures only after a controller has closed its coupling relays by command; Pulse sends nothing, so on a bus where nothing does, it reports no valid value. A resistance the monitor marks as outdated is not shown. Not read: the HV voltages and the extended status, which the monitor gives only on request. The iso175 uses other frames and is not read.
- KIND
- Insulation monitor
- MAKER
- Bender
- BUS SPEED
- 250 or 500 kbit/s
- FAULTS READ
- 4
- BUILT FROM
- The maker's documents
- PROFILE
- V1.0 by Dynam Labs
- In Pulse, open Settings → Vehicle → CAN modules.
- Choose Modules and pick Bender ISOMETER iso165C. It is already in the app.
- On a bus without a Dynam VCU, turn on Listen only for that vehicle, and Pulse sends nothing.